Handheld Digital Scanner

Uniden Handheld TrunkTracker IV Digital Police Scanner (BCD396XT) (Discontinued)

Uniden Handheld TrunkTracker IV Digital Police Scanner (BCD396XT) (Discontinued)
Uniden Handheld TrunkTracker IV Digital Police Scanner (BCD396XT) (Discontinued)
Uniden Handheld TrunkTracker IV Digital Police Scanner (BCD396XT) (Discontinued)
Uniden Handheld TrunkTracker IV Digital Police Scanner (BCD396XT) (Discontinued)
Uniden Handheld TrunkTracker IV Digital Police Scanner (BCD396XT) (Discontinued)
Uniden Handheld TrunkTracker IV Digital Police Scanner (BCD396XT) (Discontinued)
Uniden Handheld TrunkTracker IV Digital Police Scanner (BCD396XT) (Discontinued)
Uniden Handheld TrunkTracker IV Digital Police Scanner (BCD396XT) (Discontinued)

Uniden Handheld TrunkTracker IV Digital Police Scanner (BCD396XT) (Discontinued)    Uniden Handheld TrunkTracker IV Digital Police Scanner (BCD396XT) (Discontinued)

Article on the Uniden wiki for additional information. Groups per system: 20 maximum. Talkgroups per trunked system: 500 maximum. Channels per conventional system: 1000 maximum.

Scan Rate: 100 channels per second (conventional mode). Search Rate: 300 steps per second (on 5 kHz steps). System Quick Key range: 0-99. Group Quick Key range: 0-9. Preprogrammed Service Search Bands: 12.

Band Scope Span Range: 0.2 Mhz To 500 Mhz. Band Scope Step: 5 Khz To 100 Khz.

25.0000 - 512.0000 MHz. 758.0000 - 823.9875 MHz. 849.0125 - 868.9875 MHz. 894.0125 - 960.0000 MHz.

1240.0000 - 1300.0000 MHz. Power requirements: 3 AA batteries, 6V DC, or 800mA AC adapter.

Or Sony Car DC Adaptor. Bold features are newly added in this model over the BCD396T. Can be updated to support Rebanding. This scanner supports rebanding with firmware already installed. See the Updating the Firmware in Uniden DMA Scanners.

Article for the firmware link. Support for P25 Conventional channels that include NAC and TGID user differentiation (P25 One-Frequency Trunk).

Adaptive Digital Threshold - Automatically sets the digital decode threshold for APCO 25 systems. With Motorola Control Channel Only. Display UID (Unit IDs) on trunking systems.

Requires version 1.08.14 or newer firmware. System / Channel Number Tagging.

Provides rapid access to a specific system or channel. Control Channel Data Output allows the analysis of control channel data without the need to perform invasive modifications to the scanner Now supported in UniTrunker version 1.0.0.10 or newer. With Close Call Do Not Disturb. Close Call Priority (or Primary). And Close Call Temporary Store.

Location alerts, and crows-flight navigation. Independent GPS Control of Sites and Channel Groups. Supported step sizes: 5, 6.25, 7.5, 8.33, 10, 12.5,15, 20, 25, 50 or 100 kHz. Key Safe Mode - lets you hand the scanner to a novice user and prevent programming from being modified.

Private Systems - lets you flag a system so that it cannot be read out of the scanner or modified. Gives a graphic representation of signal activity. Negative Channel dropout delay (forced resume) adjustable to 0-2,5,10,30, -2, -5, -10 seconds. Temporary System, Site, Group, Channel, and Location Lockout. 500 (250 Temporary + 250 Permanent) Search Lockouts.

Frequency/ID AutoStore - automatically store frequencies from a service or limit search into a conventional system or store talk group IDs into a trunked system. 16 character text tagging for each system, site, group, channel, talkgroup, search range, location, Tone-out, and SAME.

Ability to flag a channel as Digital, Analog, or All. Search with Scan for Service and Custom Searches with assigned Quick Keys.

12 Service Searches - Public Safety, News, HAM Radio, Marine, Railroad, Air, CB Radio, FRS/GMRS, Racing, FM Broadcast, Military Air, and Special (Itinerant). Custom Search lets you program up to 10 search ranges. Also see the Fire Tone Out. Fire Tone Out Search - built-in frequency counter displays the received tones.

Independent Alert Tone Volume lets you set the volume level of the following tones: Key Beep, Emergency Alert, Channel Alert, and Close Call Alert. Also see the Priority Scan. Priority ID Scan on trunked systems. Preemptive Priority on Motorola analog systems. Adjustable Hold (scan duration 0-255 sec) per system, custom or service search.

Broadcast signal ignore while searching (TV and radio station frequencies, pagers, etc) with 10 custom bands. Wired Cloning (Will only Clone to another BCD396XT). Antenna Connector: SMA (w/BNC adapter).

The item "Uniden Handheld TrunkTracker IV Digital Police Scanner (BCD396XT) (Discontinued)" is in sale since Thursday, January 23, 2020. This item is in the category "Consumer Electronics\Radio Communication\Scanners".

The seller is "marlis_erdcta" and is located in Greenville, Indiana. This item can be shipped to United States, United Kingdom, Denmark, Romania, Slovakia, Bulgaria, Czech republic, Finland, Hungary, Latvia, Lithuania, Malta, Estonia, Greece, Portugal, Cyprus, Slovenia, Sweden, Belgium, France, Ireland, Netherlands, Poland, Spain, Italy, Germany, Austria, Switzerland, Norway, Croatia, French guiana, Iceland, Uruguay.

  • Model: BCD396XT
  • Channel Memory: 25000 Channels
  • California Prop 65 Warning: This product can expose you to chemicals including lead, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Signals Received: Analog
  • Type: Portable/Handheld
  • MPN: Does Not Apply
  • Brand: Uniden


Uniden Handheld TrunkTracker IV Digital Police Scanner (BCD396XT) (Discontinued)    Uniden Handheld TrunkTracker IV Digital Police Scanner (BCD396XT) (Discontinued)